Hydrochloric Acid Chemically Pure (CP) and has a Strength (% m/m HCl) of 30.0 – 33.0.<br />Product specifications:
Formula: HCl
Synonyms: Hydrogen chloride, chlorohydric acid and muriatic acid
Specifications
Total acidity as HCl, per cent by mass: Min. 31
Iron as Fe, ppm: Max. 1
Total halides as free chlorine, ppm: Max. 20
Specific gravity at 25oC: Min. 1.15

Category:

Description

Hydro chloric acid – Identification of Product 

CAS No: 7647-01-0

Chemical Synonyms: Chlorohydric acid,

Muriatic acid.

 

Hazards Identification 

REACH No: 01-2119484862-27-XXXX

Signal Word: Danger

Supplemental Hazard Information:

Additional Hazard Information: This substance contains no components considered to be either persistent, bio-accumulative and  toxic (PBT), or very persistent and very bio-accumulative (vPvB) at levels of 0.1% or higher.

 

Hydrochloric Acid – Hazards statements 

H290 – May be corrosive to metals.

H314 – Causes severe skin burns and eye damage.

H335 – May cause respiratory irritation.

Precautionary statements

P261 – Avoid breathing vapours.

P280 – Wear protective gloves/ protective clothing/ eye protection/ face protection.

P303 + P361 + P353 – IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.  P305 + P351 + P338 – IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to  do. Continue rinsing.

P310 – Immediately call a POISON CENTER or doctor/ physician.

 

Composition of Chemical 

Chemical Formula: HCl

EC No 1272/2008: 01-2119484862-27-XXXX

 

First Aid Measures 

General Advice: Consult a physician. Show this safety data sheet to the doctor in attendance.

If: Inhaled: Move person into fresh air. If not breathing, give artificial respiration. Consult a physician. If: Skin Contact: Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician. If: Eye Contac: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician

If: Swallowed: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult  a physician.

Important Symptoms: The most important known symptoms and effects are described in the labeling section Immediate Medical Attention: No Data Available

 

Firefighting Measures 

Extinguishing Media: Use Water spray, Alcohol-resistant foam, Dry chemical or Carbon Dioxide.

Hazards Arising: Hydrogen Chloride Gas

Advice for Firefighters: Wear self contained breathing apparatus for fire fighting if necessary.

Info for Firefighting: No Data Available

 

Accidental Release Measures

Personal Precautions: Wear respiratory protection.

Avoid breathing vapours, mist or gas.

Ensure adequate ventilation.

Evacuate personnel to safe areas.

Enviromental Precautions: Do not let product enter drains

Method for Containment: Soak up with inert absorbent material and dispose of as hazardous waste.  Keep in suitable, closed containers for disposal.

 

Hydrochloric Acid –  Handling and Storage 

Personal Precautions: Avoid contact with skin and eyes.

Avoid inhalation of vapour or mist.

Enviromental Precautions: Store in cool place.

Keep container tightly closed in a dry and well-ventilated place.

Containers which are opened must be carefully resealed and kept upright to prevent leakage.

 

Hydrochloric Acid –  Exposure Controls | Personal Protection 

Derived No Effect Level (DNEL)

Workers | Application Area | Exposure Routes | Health Effect | Value

No Data Available

Consumers | Application Area | Exposure Routes | Health Effect | Value

No Data Available

Predicted No Effect Concentration (PNEC)

No Data Available

Engineering Controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the  end of workday.

Eye/Face Protection: Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and  approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin Protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching  glove’s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with  applicable laws and good laboratory practices. Wash and dry hands.

The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from  it.

Full contact –

Material: Nitrile rubber. Minimum layer thickness: 0,4 mm

Break through time: 480 min. Material tested: Camatril®

Splash contact –

Material: Nitrile rubber. Minimum layer thickness: 0,11 mm

Break through time: 120 min. Material tested: Dermatril®

Data source: KCL GmbH, D-36124. Test method: EN374

If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE  approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar  with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use  scenario.

Body Protection: Complete suit protecting against chemicals. The type of protective equipment must be selected according to the  concentration and amount of the dangerous substance at the specific workplace.

Respiratory Protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi purpose combination type OV/AG (US) or type ABEK (EU EN 14387) respirator cartridges as a backup to engineering controls. If  the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and  approved under appropriate government standards such as NIOSH (US) or CEN (EU).

 

Hydrochloric Acid –  Physical and Chemical Properties 

Appearance: Clear to slightly Yellowish liquid

Odour: No Data Available

Odour Threshold: No Data Available

pH: No Data Available

Melting Point: No Data Available

Boiling Point: 100 °C

Flash Point: No Data Available

Evaporation: No Data Available

Flammability: No Data Available

Upper/Lower Flammability or Explosive Limits: No Data Available

Vapour pressure: No Data Available

Vapour density: No Data Available

 

Relative density: 1,1605 g/cm3

Water solubility: Miscible

Partition Coefficien: No Data Available

Auto-ignition Temperature: No Data Available

Decomposition Temperature: No Data Available

Viscosity: No Data Available

Explosive properties: No Data Available

Oxidizing properties: No Data Available

Other Safety Info: No Data Available

 

Hydrochloric Acid –  Stability and Reactivity 

Reactivity: No Data Available

Chemical Stability: Stable under recommended storage conditions.

Possibility of hazardous reactions: No Data Available

Conditions to Avoid: No Data Available

Additionally Incompatible Materials: Bases, Amines, Alkali Metals, Metals, Permanganates (e.g. Potassium Permanganate), Fluorine, Metal  Acetylides, Hexalithium Disilicide

Hazardous Decomposition Products: Hazardous decomposition products formed under fire conditions – Hydrogen Chloride gas

 

Toxicological Information 

Acute Toxicity: Inhalation: Cough, Difficulty in breathing

LCLo Inhalation – Human – 30 min – 1.970 mg/m3 (Hydrochloric Acid)

Remarks: (RTECS)

Inhalation: absorption

Skin Corrosion/Irritation: Additionally Reconstructed human epidermis (RhE) –

Result: Corrosive

(OECD Test Guideline 431)

Serious Eye damage | Eye Irritation: Bovine cornea –

Result: Corrosive (OECD Test Guideline 437)

Cell Mutagenicity: Chromosome aberration test in vitro :

Chinese hamster ovary cells –

Result: Conflicting results have been seen in different studies.

Carcinogenicity: Carcinogenicity – Did not show carcinogenic effects in animal experiments. (IUCLID).

Additionally IARC: No ingredient of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed  human carcinogen by IARC.

Reproductive toxicity: No Data Available

Specific Target Organ Toxicity – Single Exposure: Acute inhalation toxicity – Mucosal irritations, Cough, Shortness of breath.  Inhalation may lead to the formation of oedemas in the respiratory tract.

Possible damages: damage of respiratory tract, tissue damage.

Specific Target Organ Toxicity – Additionally Repeated Exposure: No Data Available

Aspiration Hazard: No Data Available

 

Ecological Information 

Ecological Toxicity: Toxicity to fish:

LC50 – Gambusia affinis (Mosquito fish) – 282 mg/l – 96 h

Ecological Persistence and degradability: No Data Available

Bioaccumulative Potential: No Data Available

Mobility in Soil: No Data Available

Results of PBT and vPvB Assessment: This substance contains no components considered to be either persistent, bio-accumulative  and toxic (PBT), or very persistent and very bio-accumulative (vPvB) at levels of 0.1% or higher.

Additionally Other Adverse Effect: May be harmful to aquatic organisms due to the shift of the pH.

Do not empty into drains.

Harmful effect due to pH shift.

Discharge into the environment must be avoided.

 

Disposal Considerations 

Waste Treatment Methods: Product –

Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material must be disposed of in accordance with  the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing  with other waste. Additionally Handle uncleaned containers like the product itself.

Contaminated packaging – Dispose of as unused product.

 

Transport Information 

UN Number: ADR/RID: 1789

IMDG: 1789

IATA: 1789

UN Shipping Hazard: ADR/RID: HYDROCHLORIC ACID

IMDG: HYDROCHLORIC ACID

IATA: Hydrochloric Acid

Transport Hazard Class: ADR/RID: 8

IMDG: 8

IATA: 8

Packaging Group: ADR/RID: II

IMDG: II

IATA: II

Enviromental Hazards: ADR/RID: no

IMDG Marine pollutant: no

IATA: no

Special Precautions: No Data Available

 

Regulatory Information 

Safety, Health and environmental regulations: Additionally This safety datasheet complies with the requirements of Regulation (EC) No.  1907/2006.

Chemical Safety Assessment: For this product a chemical safety assessment was not carried out

Additional Info: RTECS: MW4025000

Inhalation of vapors may cause:

Accordingly Burning sensation, Cough, Wheezing, Laryngitis, Shortness of breath.

Spasm, Inflammation and Edema of the Larynx.

Spasm, Inflammation and Edema of the Bronchi.

Pneumonitis, Pulmonary Edema.

After uptake of large quantities:

Cyanosis, Circulatory collapse, Respiratory arrest.

Systemic effects: Rise in blood pressure, Bradycardia.

Above all Material is extremely destructive to tissue of the mucous membranes and upper respiratory tract, eyes, and skin.  Accordingly To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.